ISO 9001 · ISO/IEC 27001 · ENS MEDIUM category · CVE Numbering Authority

Security · Intruder alarms

Intruder alarm and intrusion detection installation

Systems that detect someone's presence in an unauthorised place and trigger the alarm at exactly the right moment. We design them with the security grade that matches your risk, install them and maintain them.

  • Order INT/316/2011
  • UNE-EN 50131
  • Detection and alerting
  • Maintenance

Intrusion detection

Deterrence and alerting, easy to use every day

Intruder alarm systems are constantly evolving and becoming ever more sophisticated. But in designing them we never lose sight of the essentials: they must be easy to understand, operate and check for everyone who uses them every day.

We advise you on how your system should be designed: we study your case and work out which type of solution best suits the place you want to protect. When an intrusion is detected, an alert is triggered and the response procedures we define according to your needs are set in motion.

Systems

What an intruder alarm system includes

We combine indoor and perimeter detection, deterrence and alerting according to the place to be protected.

Alarm control panel

Receives signals from the detectors, manages the zones and triggers the alarm.

  • Zones and partitions
  • Keypads and arming fobs
  • Event log

Indoor detection

Detects presence or opening in protected spaces.

  • Volumetric detectors
  • Door and window contacts
  • Vibration detectors on walls, glazing and safes

Perimeter detection

Protects the outside before the intruder reaches the building.

  • Infrared beams
  • Perimeters of sites and industrial buildings
  • Entrances and loading areas

Fog generator

Fills the space with fog in seconds, preventing the intruder from seeing what they want to take.

  • Warehouses and high-value areas
  • Triggered by the control panel
  • Complements detection

Signalling and alerts

The alert is triggered according to the response procedures we define with you.

  • Indoor and outdoor sirens
  • Alerts to designated people
  • Ready for an alarm receiving centre

Video verification

Cameras in the area make it possible to check what triggered the alarm.

  • Integration with video surveillance
  • Verification before acting
  • Images linked to the event

Regulations

Alarm system security grades

Order INT/316/2011 of 1 February, on the operation of alarm systems in the field of private security, classifies systems into four grades according to risk and requires equipment to comply with the applicable UNE-EN standards, including the UNE-EN 50131 series for intrusion alarm systems.

Security grades (Order INT/316/2011)

  1. Grade 1

    Low risk

    Systems with audible signalling that are not connected to an alarm receiving centre or a control centre.

  2. Grade 2

    Low to medium risk

    Homes and small premises, shops and industrial units intending to connect to an alarm receiving centre or a control centre.

  3. Grade 3

    Medium to high risk

    Establishments required to have security measures and other installations that must be connected to an alarm receiving centre or a control centre.

  4. Grade 4

    High risk

    Critical infrastructure, military installations, explosives stores and cash, valuables or precious metals depository companies, among others.

Indicative summary: each grade is defined by the text of Order INT/316/2011.

Environmental classes (UNE-EN 50131-1)

  • Class I Indoor
  • Class II Indoor general
  • Class III Sheltered outdoor or indoor under extreme conditions
  • Class IV Outdoor general

Each piece of equipment must have the system's grade and the environmental class of the place where it is installed. Installing and maintaining systems connected to an alarm receiving centre are activities reserved for authorised security companies (Law 5/2014 on Private Security).

Methodology

How we run an intruder alarm project

  1. Risk analysis

    We study the site, its access points, its hours of use and what needs protecting.

  2. Design

    We set the security grade, zones, detectors and alert mechanisms.

  3. Installation

    Installation, control panel programming and testing of each detector.

  4. Training

    We show each user how to arm, disarm and check the system.

  5. Maintenance

    Certified preventive inspections and priority corrective maintenance.

Integrated security

Your alarm, coordinated with the rest of your security

A single team designs, installs and maintains all the building's systems.

CMMS and customer portal

Your alarm maintenance, scheduled and certified

Our in-house CMMS generates your system's inspection schedule, guides the technician with an item-by-item checklist and issues the inspection certificate. From your customer portal you can check everything and log a request whenever you need to.

  • Preventive inspection schedule generated from the contract
  • Inspection certificate issued and sent at the end of each period
  • Urgent requests notified by email, Telegram and, at weekends, SMS
  • Job reports signed on a phone, as PDFs with a SHA-256 hash and sent by email
Monthly calendar of preventive maintenance by building and system, with its status
Real screenshot of our CMMS with a demo client (fictitious data).

Sectors

Intruder alarms for every type of installation

Public buildings

Administrative offices, libraries, sports facilities and municipal facilities.

Schools and colleges

Schools, secondary schools and university buildings that stand empty outside teaching hours.

Industry and industrial buildings

Large sites with an outer perimeter, machinery and warehouses.

Warehousing and logistics

High-value goods and loading areas that call for detection and fog.

Offices and shops

Premises and offices that need an alarm that is easy to use every day.

Technical installations

Isolated huts, tanks and telecommunications centres.

Security systems

Other systems we design, install and maintain

Fire extinguishers next to fire safety signage

Fire protection

Detection, alarm, suppression and maintenance under the RIPCI.

Find out more
CCTV dome camera on the ceiling of an industrial building

Video surveillance

IP cameras, recording and viewing in compliance with the GDPR.

Find out more
Hand holding a card up to an access control reader

Access control

People and vehicles, with card, keypad, fingerprint or number plate.

Find out more
Technician inspecting an electrical panel

Maintenance

Preventive and corrective maintenance of security installations.

Find out more

Frequently asked questions

Common questions about intruder alarm systems

What security grade does my alarm system need?

It is determined by the risk of the site and whether the system will be connected to an alarm receiving centre. Order INT/316/2011 defines four grades, from 1 (low risk, not connected) to 4 (high risk, such as critical infrastructure). We study your case and tell you which grade applies.

What is the environmental class of alarm equipment?

Standard UNE-EN 50131-1 classifies equipment according to the environment in which it will operate, from Class I (indoor) to Class IV (outdoor general). An outdoor detector must have the appropriate environmental class, in addition to the system's security grade.

Can the alarm be connected to an alarm receiving centre (ARC)?

Yes. Installing and maintaining systems connected to an alarm receiving centre are private security activities reserved for authorised security companies (Law 5/2014 on Private Security). We leave the system ready for connection with the security grade required by the regulations.

Does an alarm replace security bars or locks?

No, it complements them. Intruder alarm systems play a key role in deterrence and alerting, and work best alongside physical measures such as bars, security glazing or locks.

Can it be integrated with video surveillance and access control?

Yes. We design security as a whole: intrusion detection can be combined with video surveillance to verify alarms and with access control to know who was authorised.

How is an alarm system maintained?

With scheduled preventive inspections of the control panel, detectors, batteries and communications, and repairs when something fails. At the end of each inspection we issue its certificate and everything is visible in your customer portal. More information in security systems maintenance.

Do you want to protect a building against intrusion?

We analyse the risk, tell you the right security grade and design, install and maintain the system.